Search
Ask for an offer
Call me back
Download leaflets
Business data
Technical specifications
| The VebaBox characterizes itself by the excellent specifications and reliability compared to a cooling van. To give an example: Each VebaBox will be tested on a maximal temperature-divergence of +or – 1°C. Also shall the VebaBox be tested on the set temperature within 20 min. After approval of a checklist of over 60 issues the VebaBox will be packed and send to the reseller. So it’s not for nothing that the VebaBox will be sold with a 2 year warranty. |
|
Technical specifications:
| PARAMETER |
MIN or TYP | MAX or TOL | UNIT | REMARKS |
| Weight | 60 | 150 | KG | Depends of configuration. |
| DC Voltage | 12 | ±10 % | Volt | |
| AC Voltage | 230 | ±10 % | Volt | |
| DC Current | 5 | 30 | Ampere | Depends of configuration. |
| AC Power | 180 | 1080 | Watt | Depends of configuration. |
| Temperature setpoint cool | +2 | +8 | ºC | |
| Temperature setpoint freeze | -18 | +8 | ºC | |
| Ambient temp cool | +40 | ºC | ||
| Ambient temp freeze | +30 | ºC | ||
| K-Waarde Vebabox | 0,685 | ±5 % | W/m².C |
| PART or ITEM | DESCRIPTION | REMARKS | |
| Material Vebabox | Sandwich panel (trespa–pur–trespa) | Thickness trespa is 2mm, thickness PUR is 46mm. | |
| Compressor cabinet | Coated metal sheet 1,5 mm, RAL9002 | ||
| Cooling technology | One or more compressors | Depends of requirements. | |
| Refrigerant gas | R134a (CF3-CH2F) | ||
| Temperature control | Electronic with PTC sensor | If necessary, with dead band zone. | |
| Temperature display | Digital display on control unit | Red illuminated 7 segment display. | |
| Mains of alarm | Visual on temperature display | Audio by mains of buzzer. | |
| Alarm setup |
Upper alarm by +3ºC above setpoint
Lower alarm by -3ºC under setpoint
|
Can be set on other value or disable alarm. | |
| Approvals | ATP | K-Waarde | |
| ATP | Refregerating capacity | ||
| CE | 89/336EEC and 73/23EEC | ||
United Kingdom